DLMS/COSEM protocol is not specific to electricity metering, it is also used for gas, water and heat metering. Oleh karena itu, kamu bisa memilih jenis listrik sesuai kebutuhan. Kini kamu juga telah mengetahui kelebihan dan kekurangannya masing-masing. Nah, itu dia perbedaan listrik prabayar dan pascabayar, Sahabat Prima. Susceptibility to electromagnetic fields conforming to IEC 6ġ.The IEC TC13 WG14 groups the DLMS specifications under the common heading: 'Electricity metering data exchange - The DLMS/COSEM suite'. Privasi sedikit terganggu karena ada orang PLN yang akan mengecek meteran listrik sewaktu-waktu. Immunity to impulse waves conforming to IEC 6Įlectrical fast transient/burst immunity test conforming to IEC 6 Programmablity (logic and math functions)Ĭlass 0.2S energy conforming to IEC 62053-23Ĭlass 0.2 energy conforming to ANSI C12.20Ĭlass 0.2S energy conforming to IEC 62053-22Įnvironment electromagnetic compatibilityĮlectrostatic discharge immunity test conforming to IEC 6Ĭonducted RF disturbances conforming to IEC 6 These meters give utilities the tools to manage complex energy supply contracts that include commitments to power quality. Integration with EcoStruxure Power Operations software through multiple communication channels and protocols, Including Itron MV-90, Modbus, DNP, DLMS, IEC 61850. You can find the following accessories for ION8650: some input/output expanders, A-base adaptors and communication cable. Operating environment of -40 to +85C Humidity rating of 5% to 95% Altitude up to 3000 m. Switchboard form factor, setting available in form 9/29/35/36S Base wiring break out panel.

Mechanical dimensions are 285 mm in height, 163 mm in width and 228 mm in depth, for a product weight of 7 kg. Multiple communication ports include: RS232/RS485, RS485, Infrared (ANSI type II) and Ethernet 10/100 BASE-T. Onboard input output configurtion include 3 digital inputs, 2 pulse outputs and 4 relay outputs plus up to 3 dry contact sensing inputs. Wide control power range thanks to an external power source: pigtail 160 to 277 VAC or 200 to 300 VDC. Providing 1024 samples per cycle with Voltage inputs of 57-277 VAC L-N / 100-480 VAC L-L Current inputs of 1 A, 2 A, and 5 A. The ability to timestamp events to +/-1 ms utilizing time synchronization methods that include SNTP, IRIG-B, GPS ASCII (RS485) and network time set function. With 32 MB of memory to support data logs, alarms, RMS logging, historical logs, event logs, revenue logs, GPS synch and Time of Use. Enable for the user acces to the analysis of energy, bill verification, cost allocation and more. The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. The meter can be the solution for transmission or distribution network. These meters offer a wide versatility of feature and total performance. The PowerLogic ION8650 series meters are ideal for energy, power quality metering and independent power producers.